This is a public organization operationally decentralized that is a legal entity with its own assets. Its mission is to contribute to sustainable development, conservation and preservation of natural resources through: Environmental Impact Assessment, Citizen Participation and Indigenous Consultation and Relevance Consultation.
Descripción.
Electrical Substation (ES)
Power facility that through equipment receives, manages and delivers electricity from and to lines. The ES are responsible for transforming voltage, frequency or connection of two or more transmission line circuits.
Power Protection System
Devices and equipment required to detect and solve any faults that could affect the protected equipment. This system disconnects a faulty section as quickly as possible to minimize system disturbances, ensure human safety and prevent equipment and system damage. The power protection system includes circuit breakers, protection schemes, current and potential transformers, teleprotection channels and
Diagonal for a Substation with a one breaker and a half configuration
quipment used to connect a power facility to the transmission network, in general, it consists of three circuit breakers, disconnect switches, instrument transformers, surge arresters, wave traps, coupling capacitors, etc.c.
Derivation (Tap-Off Connection)
A single connection that is started from a transmission line in order to withdraw or supply power, as long as this line does not belong to the Trunk Transmission System. Conditions for executing tap-off connections are regulated by Article 3-24 and 3-25 of the Technical Standards.
Coordinated Party (power generation company, power transmission company, complementary services provider, free customer or regulated customer)
Coordinated Party (Power generation company, power transmission company, complementary services provider, free customer or regulated customer) Anyone exploiting facilities that are interconnected in any way shall be understood to be a Coordinated Party, whether these be: a) Power plants; b) Trunk, subtransmission or additional systems transmission lines; c) HVDC links; d) Interconnection lines between
Connection Point
The Substation busbar or transmission line starting point, where facilities used by different coordinated parties are interconnected, or facilities that, although they are used by the same coordinated party, are in different facility categories (see term “coordinated party”). A power plant connection point to a transmission network is the high-voltage busbar of its power transformers.
Bay
Equipment that connects a power facility to the transmission network, in general, it consists of three circuit breakers, disconnect switches, instrument transformers, surge arresters, wave traps, coupling capacitors, etc.